C4KX-PWR-750AC-F/2
C4KX-PWR-750AC-F/2 Обзор
(3.99 x 5.46 x 36.27 cm)
•6 A @ 200 VAC (max)
Figure 1 shows the C4KX-PWR-750AC-F= Features. C4KX-PWR-750AC-F/2 is similar with it.
Note:
① |
FAIL LED (amber) |
② |
OK LED (green) |
③ |
AC power cord receptacle (IEC 60320 C15) |
④ |
Release lever (color-coded for airflow direction. Burgundy indicates front-to-back airflow; blue indicates back-to-front airflow) |
⑤ |
Retention clip |
⑥ |
Fan (directional arrow on top indicates airflow direction) |
C4KX-PWR-750AC-F/2 Specification |
|
AC-input type |
Autoranging input with power factor correction (PFC) |
AC-input voltage |
100 to 240 VAC (115/230 VAC nominal) single-phase |
AC-input current |
•11 A @ 100 VAC (max) •6 A @ 200 VAC (max) |
AC-input frequency |
47 to 63 Hz (50/60 Hz nominal) |
Branch circuit requirement |
Each chassis power supply should have its own dedicated, fused-branch circuit: •For North America—15 A •For International—Circuits should be sized to local and national codes •All AC power supply inputs are fully isolated. •Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. |
Power supply output capacity |
750 W |
Power supply output |
•12 VDC @ 62 A •3.3 VDC @ 3 A |
Output holdup time |
16 ms minimum (20 ms @ 60% load) |
BTU (total output) Note:1000 BTU/hour = 293 W |
1122 BTU/hour (nominal) 1365 BTU/hour (max) |
AC-input power supply dimensions |
1.57 x 2.15 x 14.28 in |
Weight |
2 lb (0.91 kg) |